Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Am J Emerg Med ; 49: 172-177, 2021 Nov.
Article in English | MEDLINE | ID: covidwho-1260367

ABSTRACT

BACKGROUND: Airborne personal protective equipment is required for healthcare workers when performing aerosol-generating procedures on patients with infectious diseases. Chest compressions, one of the main components of cardiopulmonary resuscitation, require intense and dynamic movements of the upper body. We aimed to investigate the protective effect of tight-fitting powered air-purifying respirators (PAPRs) during chest compressions. METHODS: This single-center simulation study was performed from February 2021 to March 2021. The simulated workplace protection factor (SWPF) is the concentration ratio of ambient particles and particles inside the PAPR mask; this value indicates the level of protection provided by a respirator when subjected to a simulated work environment. Participants performed continuous chest compressions three times for 2 min each time, with a 4-min break between each session. We measured the SWPF of the tight-fitting PAPR during chest compression in real-time mode. The primary outcome was the ratio of any failure of protection (SWPF <500) during the chest compression sessions. RESULTS: Fifty-four participants completed the simulation. Overall, 78% (n = 42) of the participants failed (the measured SWPF value was less than 500) at least one of the three sessions of chest compressions. The median value and interquartile range of the SWPF was 4304 (685-16,191). There were no reports of slipping down of the respirator or mechanical failure during chest compressions. CONCLUSIONS: Although the median SWPF value was high during chest compressions, the tight-fitting PAPR did not provide adequate protection.


Subject(s)
Cardiopulmonary Resuscitation/adverse effects , Protective Factors , Respiratory Protective Devices/standards , Adult , Air Filters/standards , Air Filters/statistics & numerical data , Cardiopulmonary Resuscitation/methods , Female , Humans , Infection Control/methods , Infection Control/standards , Infection Control/statistics & numerical data , Male , Respiratory Protective Devices/statistics & numerical data , Surveys and Questionnaires
2.
J Cardiol Cases ; 22(6): 260-264, 2020 Dec.
Article in English | MEDLINE | ID: covidwho-670567

ABSTRACT

We treated two patients with COVID-19 pneumonia requiring mechanical ventilation. Case 1 was a 73-year-old Japanese man. Computed tomography (CT) revealed ground-glass opacities in both lungs. He had severe respiratory failure with a partial pressure of oxygen in arterial blood/fraction of inspiratory oxygen ratio (P/F ratio) of 203. Electrocardiogram showed a heart rate (HR) of 56 beats/min, slight ST depression in leads II, III, and aVF, and mild saddle-back type ST elevation in leads V1 and V2. High-sensitivity cardiac troponin T (cTnT) level was slightly elevated. Despite a high fever and hypoxemia, his HR remained within 50-70 beats/min. Case 2 was a 52-year-old Japanese woman. CT revealed ground-glass opacities in the lower left lung. Electrocardiogram showed a HR of only 81 beats/min, despite a body temperature of 39.2 °C, slight ST depression in leads V4, V5, V6, and a prominent U wave in multiple leads. She had an elevated cTnT and a P/F ratio of 165. Despite a high fever and hypoxemia, her HR remained within 50-70 beats/min. Both patients had a poor compensatory increase in their HR, despite their critical status. Relative bradycardia could be a cardiovascular complication and is an important clinical finding in patients with COVID-19. .

SELECTION OF CITATIONS
SEARCH DETAIL